Quenching-rate determination for standard steel tensile specimens

A vertical tube furnace and a four-channel digital storage oscilloscope have been used to determine quench rates for standard tensile specimens of a martensitic stainless steel 1.4914. The quenching media examined were air, oil and water. Theoretical calculations were made, based on convection heat-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of materials science 1991-04, Vol.26 (7), p.1847-1850, Article 1847
Hauptverfasser: ADETUNJI, G. J, FAULKNER, R. G, LITTLE, E. A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A vertical tube furnace and a four-channel digital storage oscilloscope have been used to determine quench rates for standard tensile specimens of a martensitic stainless steel 1.4914. The quenching media examined were air, oil and water. Theoretical calculations were made, based on convection heat-transfer approaches, which quantify the heat flow from the specimen surfaces during cooling. Experimental data are in reasonable agreement with predicted values. Graphs. 7 ref.--AA
ISSN:1573-4803
0022-2461
1573-4803
DOI:10.1007/bf00543613