An evaluation of analog and numerical techniques for unsteady heat transfer measurement with thin-film gauges in transient facilities
The importance of frequency response considerations in the use of thin-film gauges for unsteady heat transfer measurements in transient facilities is considered, and methods for evaluating it are proposed. A departure frequency response function is introduced and illustrated by an existing analog ci...
Gespeichert in:
Veröffentlicht in: | Experimental thermal and fluid science 1991-05, Vol.4 (3), p.333-342 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The importance of frequency response considerations in the use of thin-film gauges for unsteady heat transfer measurements in transient facilities is considered, and methods for evaluating it are proposed. A departure frequency response function is introduced and illustrated by an existing analog circuit. A Fresnel integral temperature which possesses the essential features of the film temperature in transient facilities is introduced and is used to evaluate two numerical algorithms. Finally, criteria are proposed for the use of finite-difference algorithms for the calculation of the unsteady heat flux from a sampled temperature signal. |
---|---|
ISSN: | 0894-1777 1879-2286 |
DOI: | 10.1016/0894-1777(91)90050-2 |