Time series analysis of the in-hospital diagnostic process in suspected pulmonary embolism evaluated by computed tomography: An explorative study
•The demand for CTPA shows a distinct diurnal distribution depending on the sector of patient care.•The processing time of CTPA is shorter during night hours than during daytime.•The workflow in radiology departments can be evaluated using time series analysis. This retrospective study aims to analy...
Gespeichert in:
Veröffentlicht in: | European journal of radiology 2021-07, Vol.140, p.109758-109758, Article 109758 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The demand for CTPA shows a distinct diurnal distribution depending on the sector of patient care.•The processing time of CTPA is shorter during night hours than during daytime.•The workflow in radiology departments can be evaluated using time series analysis.
This retrospective study aims to analyze the distribution of demand and the duration of the diagnostic workup of suspected pulmonary embolism (PE) using computed tomography pulmonary angiography (CTPA).
Time data from physical examination to report creation were identified for each CTPA in 2013 and 2018 at a tertiary hospital. Multivariable multinomial logistic and linear regression models were used to evaluate differences between 3 time intervals (I1: 6am-2pm, I2: 2pm-10pm, I3: 10pm-6am). A cosinor model was applied to analyze the amount of CTPA per hour.
The relative demand for CTPA from the emergency room was lower in l1 compared to l2 and l3 (I1/I2: odds ratio (OR) 0.84, 95 % confidence interval (CI) 0.78−0.91; I1/I3: OR 0.80, 95 % CI 0.72−0.89; peak 4:23 pm). Requests for in-patients displayed a tendency towards I1 (I1/2: OR 1.15, 95 % CI 1.06–1.24; l1/l3: OR 1.19, 95 % CI 1.07–1.33; peak 1:54 pm). The time from CTPA request to study was shorter in I3 compared to I1 and I2 in 2013 (I1/I3: ratio 5.23, 95 % CI 3.38–8.10; I2/I3: ratio 3.50, 95 % CI 2.24–5.45) and 2018 (I1/I3: ratio 2.27, 95 % CI 1.60–3.22; I2/I3: ratio 2.11, 95 % CI 1.50–2.97). This applied similarly to fatal cases (I1/I3: ratio 2.91, 95 % CI 1.78–4.75; I2/I3: ratio 2.45, 95 % CI1.52−3.95).
The temporal distribution of demand for CTPA depends on the sector of patient care and the processing time differs substantially during the day. Time series analysis can reveal such coherences and may help to optimize workflows in radiology departments. |
---|---|
ISSN: | 0720-048X 1872-7727 |
DOI: | 10.1016/j.ejrad.2021.109758 |