Attitude is everything: keep probe pitch neutral during side‐fire prostate biopsy. A simulator study

Objectives To develop and validate on a simulator a learnable technique to decrease deviation of biopsied cores from the template schema during freehand, side‐fire systematic prostate biopsy (sPBx) with the goal of reducing prostate biopsy (PBx) false‐negatives, thereby facilitating earlier sampling...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJU international 2021-11, Vol.128 (5), p.615-624
Hauptverfasser: Zhang, Zhou, Lampotang, Samsun, Yu, Yichao, Acar, Yahya A., Wakim, Jonathan, Mei, Vincent, Ahmad, Ardalan E., Shenot, Patrick, Lee, Jason, Perlis, Nathan, Moy, Louis, Johnson, William T., DeStephens, Anthony, Bigos, Andre K., Lizdas, David E., Stringer, Thomas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives To develop and validate on a simulator a learnable technique to decrease deviation of biopsied cores from the template schema during freehand, side‐fire systematic prostate biopsy (sPBx) with the goal of reducing prostate biopsy (PBx) false‐negatives, thereby facilitating earlier sampling, diagnosis and treatment of clinically significant prostate cancer. Participants and Methods Using a PBx simulator with real‐time three‐dimensional visualization, we devised a freehand, pitch‐neutral (0°, horizontal plane), side‐fire, transrectal ultrasonography (TRUS)‐guided sPBx technique in the left lateral decubitus position. Thirty‐four trainees on four Canadian and US urology programmes learned the technique on the same simulator, which recorded deviation from the intended template location in a double‐sextant template as well as the TRUS probe pitch at the time of sampling. We defined deviation as the shortest distance in millimeters between a core centre and its intended template location, template deviation as the mean of all deviations in a template, and mastery as achieving a template deviation ≤5.0 mm. Results All results are reported as mean ± sd. The mean absolute pitch and template deviation before learning the technique (baseline) were 8.2 ± 4.1° and 8.0 ± 2.7 mm, respectively, and after mastering the technique decreased to 4.5 ± 2.7° (P = 0.001) and 4.5 ± 0.6 mm (P < 0.001). Template deviation was related to mean absolute pitch (P < 0.001) and increased by 0.5 mm on average with each 1° increase in mean absolute pitch. Participants achieved mastery after practising 3.9 ± 2.9 double‐sextant sets. There was no difference in time to perform a double‐sextant set at baseline (277 ± 102 s) and mastery (283 ± 101 s; P = 0.39). Conclusion A pitch‐neutral side‐fire technique reduced template deviation during simulated freehand TRUS‐guided sPBx, suggesting it may also reduce PBx false‐negatives in patients in a future clinical trial. This pitch‐neutral technique can be taught and learned; the University of Florida has been teaching it to all Urology residents for the last 2 years.
ISSN:1464-4096
1464-410X
DOI:10.1111/bju.15445