Effective easing of the side effects of copper intrauterine devices using ultra-fine-grained Cu-0.4Mg alloy
Copper intrauterine device is one of the most adopted contraceptive methods with high effectiveness (over 99 %), low cost, spontaneous reversibility and long-lasting usage. However, the side effects induced from the initial burst release of copper ions (Cu2+) hinder the continuation of the Cu-IUD ma...
Gespeichert in:
Veröffentlicht in: | Acta biomaterialia 2021-07, Vol.128, p.523-539 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Copper intrauterine device is one of the most adopted contraceptive methods with high effectiveness (over 99 %), low cost, spontaneous reversibility and long-lasting usage. However, the side effects induced from the initial burst release of copper ions (Cu2+) hinder the continuation of the Cu-IUD made of Coarse-Grained Copper (CG Cu). We proposed to tailor the bio-corrosion behaviors of better control of Cu2+ release via the addition of bioactive Mg into the Ultra-Fine Grained (UFG) Bulk Cu. Thus, UFG bulk Cu with 0.4 wt.% Mg was produced via equal-channel angular pressing. The microstructures of the UFG Cu-0.4Mg was observed using electron backscatter diffraction and transmission electron microscopy techniques. The in vitro long-term corrosion behaviors in simulated uterine fluid, cytotoxicity to four cell lines, in vivo biocompatibility and contraceptive efficacy were all studied on CG Cu, UFG Cu and UFG Cu-0.4Mg materials. The results demonstrate that both the ultrafine grains and the addition of bioactive Mg into Cu contribute to the suppression of the burst release of Cu2+ in the initial stage and the maintenance of high level Cu2+ in long-term release. Moreover, the UFG Cu-0.4Mg also exhibited much improved cell and tissue biocompatibility from both the in vitro and in vivo evaluations. Therefore, the contraceptive efficacy of UFG Cu-0.4Mg is still maintained as high as the CG Cu and UFG Cu while the side effects are significantly eased, suggesting the high potential of the UFG Cu-0.4Mg alloy as a new upgrading or alternative material for Cu-IUD.
The side effects from burst release of Cu2+ at the initial implantation stage of Cu-containing intrauterine devices (Cu-IUD) is one of the main drawbacks of these devices. In this work, an ultra-fine-grained Cu (UFG Cu) alloyed with a low amount of bioactive Mg was used for a Cu-IUD. The UFG Cu-0.4Mg alloy exhibited suppressed burst release of Cu2+ at initial implantation, while active Cu2+ release for long-term usage was maintained, comparable to coarse-grained pure Cu. Furthermore, the UFG Cu-0.4Mg alloy displayed significantly improved biocompatibility with human uterus cells and a much decreased inflammatory response within the uterus. Therefore, the side effects from Cu-IUD were eased, while high antifertility efficacy of the UFG Cu-0.4Mg alloy was maintained. The UFG Cu-0.4Mg alloy is promising for Cu-IUD.
[Display omitted] |
---|---|
ISSN: | 1742-7061 1878-7568 |
DOI: | 10.1016/j.actbio.2021.04.037 |