Analytical validation of an automated assay for the measurement of adenosine deaminase (ADA) and its isoenzymes in saliva and a pilot evaluation of their changes in patients with SARS-CoV-2 infection

The aim of the present study was to validate a commercially available automated assay for the measurement of total adenosine deaminase (tADA) and its isoenzymes (ADA1 and ADA2) in saliva in a fast and accurate way, and evaluate the possible changes of these analytes in individuals with SARS-CoV-2 in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2021-08, Vol.59 (9), p.1592-1599
Hauptverfasser: Franco-Martínez, Lorena, Tecles, Fernando, Torres-Cantero, Alberto, Bernal, Enrique, San Lázaro, Indra, Alcaraz, María José, Vicente-Romero, María R., Lamy, Elsa, Sánchez-Resalt, Cristina, Rubio, Camila P., Tvarijonaviciute, Asta, Martínez-Subiela, Silvia, Cerón, José J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of the present study was to validate a commercially available automated assay for the measurement of total adenosine deaminase (tADA) and its isoenzymes (ADA1 and ADA2) in saliva in a fast and accurate way, and evaluate the possible changes of these analytes in individuals with SARS-CoV-2 infection. The validation, in addition to the evaluation of precision and accuracy, included the analysis of the effects of the main procedures that are currently being used for SARS-CoV-2 inactivation in saliva and a pilot study to evaluate the possible changes in salivary tADA and isoenzymes in individuals infected with SARS-CoV-2. The automated assay proved to be accurate and precise, with intra- and inter-assay coefficients of variation below 8.2%, linearity under dilution linear regression with R close to 1, and recovery percentage between 80 and 120% in all cases. This assay was affected when the sample is treated with heat or SDS for virus inactivation but tolerated Triton X-100 and NP-40. Individuals with SARS-CoV-2 infection (n=71) and who recovered from infection (n=11) had higher mean values of activity of tADA and its isoenzymes than healthy individuals (n=35). tADA and its isoenzymes ADA1 and ADA2 can be measured accurately and precisely in saliva samples in a rapid, economical, and reproducible way and can be analyzed after chemical inactivation with Triton X-100 and NP-40. Besides, the changes observed in tADA and isoenzymes in individuals with COVID-19 open the possibility of their potential use as non-invasive biomarkers in this disease.
ISSN:1434-6621
1437-4331
DOI:10.1515/cclm-2021-0324