Predictor analysis of 1-year restenosis after percutaneous transluminal angioplasty for femoropopliteal stenotic lesions using intravascular ultrasound

This retrospective, single-center study evaluated the patency rate and predictors of restenosis after percutaneous transluminal angioplasty (PTA) for femoropopliteal stenotic lesions using intravascular ultrasound. We assessed 78 de novo femoropopliteal stenotic lesions (64 patients; mean age, 73.6 ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Heart and vessels 2021-11, Vol.36 (11), p.1661-1669
Hauptverfasser: Kakizaki, Shunsuke, Kozuki, Amane, Kijima, Yoichi, Nagoshi, Ryoji, Fujiwara, Ryudo, Shibata, Hiroyuki, Suzuki, Atsushi, Fujimoto, Daichi, Kyo, Syokan, Masuko, Eri, Miyata, Tomohiro, Shite, Junya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This retrospective, single-center study evaluated the patency rate and predictors of restenosis after percutaneous transluminal angioplasty (PTA) for femoropopliteal stenotic lesions using intravascular ultrasound. We assessed 78 de novo femoropopliteal stenotic lesions (64 patients; mean age, 73.6 ± 9.4 years; average lesion length, 59.8 mm) that underwent PTA under intravascular ultrasound guidance. The primary endpoint was 1-year primary patency. The 1-year primary patency rate was 63%. The frequency of insulin use was significantly greater (44% vs. 12%, p  = 0.005), and lesions were significantly longer (77.8 mm vs. 49.2 mm, p  = 0.047) in the restenosis group than in the non-restenosis group. The pre-intervention reference lumen area and minimum lumen area (MLA) were significantly smaller in the restenosis group (reference lumen area: 19.7 ± 6.7 mm 2 vs. 23.7 ± 7.4 mm 2 , p  = 0.017; MLA 3.9 ± 2.8 mm 2 vs. 5.7 ± 3.9 mm 2 , p  = 0.026; respectively). The MLA was significantly smaller and the maximum angle of dissection was significantly larger in the restenosis group (MLA 9.3 mm 2 vs. 12.3 mm 2 , p  = 0.013; maximum angle of dissection: 104.1° vs. 69.6°, p  = 0.003; respectively) among post-intervention parameters. Multivariate analysis revealed that the independent predictors of 1-year restenosis were the large post-intervention maximum angle of dissection and insulin use. Per receiver operating curve analysis, the best cut-off value of the post-intervention maximum angle of dissection that predicted 1-year restenosis was 70.2° (sensitivity 72.4%, specificity 63.3%, area under the curve 0.70, p  = 0.004). In conclusion, the 1-year primary patency rate after PTA for relatively short stenotic femoropopliteal lesions was 63%. The large post-intervention maximum angle of dissection, measured using intravascular ultrasound, and insulin use were independent predictors of restenosis after PTA.
ISSN:0910-8327
1615-2573
DOI:10.1007/s00380-021-01845-8