Smartphone electrocardiogram for detecting atrial fibrillation after a cerebral ischaemic event: a multicentre randomized controlled trial

Abstract Aims Atrial fibrillation (AF) is a preventable cause of ischaemic stroke but it is often undiagnosed and undertreated. The utility of smartphone electrocardiogram (ECG) for the detection of AF after ischaemic stroke is unknown. The aim of this study is to determine the diagnostic yield of 3...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2021-07, Vol.23 (7), p.1016-1023
Hauptverfasser: Koh, Keng Tat, Law, Wan Chung, Zaw, Win Moe, Foo, Diana Hui Ping, Tan, Chen Ting, Steven, Anderson, Samuel, Desmond, Fam, Tem Lom, Chai, Ching Hua, Wong, Zhai Sing, Xaviar, Sivaraj, Bhavnani, Chandan Deepak, Tan, Jason Seng Hong, Oon, Yen Yee, Said, Asri, Fong, Alan Yean Yip, Ong, Tiong Kiam
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Aims Atrial fibrillation (AF) is a preventable cause of ischaemic stroke but it is often undiagnosed and undertreated. The utility of smartphone electrocardiogram (ECG) for the detection of AF after ischaemic stroke is unknown. The aim of this study is to determine the diagnostic yield of 30-day smartphone ECG recording compared with 24-h Holter monitoring for detecting AF ≥30 s. Methods and results In this multicentre, open-label study, we randomly assigned 203 participants to undergo one additional 24-h Holter monitoring (control group, n = 98) vs. 30-day smartphone ECG monitoring (intervention group, n = 105) using KardiaMobile (AliveCor®, Mountain View, CA, USA). Major inclusion criteria included age ≥55 years old, without known AF, and ischaemic stroke or transient ischaemic attack (TIA) within the preceding 12 months. Baseline characteristics were similar between the two groups. The index event was ischaemic stroke in 88.5% in the intervention group and 88.8% in the control group (P = 0.852). AF lasting ≥30 s was detected in 10 of 105 patients in the intervention group and 2 of 98 patients in the control group (9.5% vs. 2.0%; absolute difference 7.5%; P = 0.024). The number needed to screen to detect one AF was 13. After the 30-day smartphone monitoring, there was a significantly higher proportion of patients on oral anticoagulation therapy at 3 months compared with baseline in the intervention group (9.5% vs. 0%, P = 0.002). Conclusions Among patients ≥55 years of age with a recent cryptogenic stroke or TIA, 30-day smartphone ECG recording significantly improved the detection of AF when compared with the standard repeat 24-h Holter monitoring. Graphical Abstract
ISSN:1099-5129
1532-2092
DOI:10.1093/europace/euab036