Runout tracking in gear motors using a microsensor based on all-fiber Fabry-Perot interferometry
A novel radial runout measurement method for gear motors using a microsensor based on all-fiber Fabry-Perot interferometry is investigated. In order to achieve the fault diagnosis, in this method, a single-mode fiber is put forward as a sensor to measure radial runout of the rotating shaft. The perf...
Gespeichert in:
Veröffentlicht in: | Applied optics (2004) 2021-02, Vol.60 (6), p.1544-1549 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A novel radial runout measurement method for gear motors using a microsensor based on all-fiber Fabry-Perot interferometry is investigated. In order to achieve the fault diagnosis, in this method, a single-mode fiber is put forward as a sensor to measure radial runout of the rotating shaft. The performance of the proposed sensor has been compared to a Portable Digital Vibrometer-100 laser vibrometer for validation purposes, and the results show that the difference between them is approximately ±0.55µ
. |
---|---|