Rapid, Sensitive, and Specific Severe Acute Respiratory Syndrome Coronavirus 2 Detection: A Multicenter Comparison Between Standard Quantitative Reverse-Transcriptase Polymerase Chain Reaction and CRISPR-Based DETECTR
Abstract Background Recent advances in CRISPR-based diagnostics suggest that DETECTR, a combination of reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) and subsequent Cas12 bystander nuclease activation by amplicon-targeting ribonucleoprotein complexes, could be a faster and ch...
Gespeichert in:
Veröffentlicht in: | The Journal of infectious diseases 2021-02, Vol.223 (2), p.206-213 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
Recent advances in CRISPR-based diagnostics suggest that DETECTR, a combination of reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) and subsequent Cas12 bystander nuclease activation by amplicon-targeting ribonucleoprotein complexes, could be a faster and cheaper alternative to quantitative reverse-transcription polymerase chain reaction (qRT-PCR) without sacrificing sensitivity and/or specificity.
Methods
In this study, we compare DETECTR with qRT-PCR to diagnose coronavirus disease 2019 on 378 patient samples. Patient sample dilution assays suggest a higher analytical sensitivity of DETECTR compared with qRT-PCR; however, this was not confirmed in this large patient cohort, where we report 95% reproducibility between the 2 tests.
Results
These data showed that both techniques are equally sensitive in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) providing additional value of DETECTR to the currently used qRT-PCR platforms. For DETECTR, different guide ribonucleic acids can be used simultaneously to obviate negative results due to mutations in N-gene. Lateral flow strips, suitable as a point-of-care test, showed a 100% correlation to the high-throughput DETECTR assay. More importantly, DETECTR was 100% specific for SARS-CoV-2 relative to other human coronaviruses.
Conclusions
Because there is no need for specialized equipment, DETECTR could be rapidly implemented as a complementary technically independent approach to qRT-PCR thereby increasing the testing capacity of medical microbiological laboratories and relieving the existent PCR platforms for routine non-SARS-CoV-2 diagnostic testing.
SARS-CoV-2 detection using DETECTR has 95% concordance with qRT-PCR. DETECTR is highly specific for SARS-CoV-2 and equally sensitive compared with qRT-PCR. DETECTR point-of-care and DETECTR high throughput represent independent alternatives to qRT-PCR platforms for SARS-CoV-2 detection. |
---|---|
ISSN: | 0022-1899 1537-6613 |
DOI: | 10.1093/infdis/jiaa641 |