Deep lateral orbital decompression for Graves orbitopathy: a systematic review

Purpose To systematically review the literature on the deep lateral orbital decompression (DLD). Methods The authors searched the MEDLINE, Lilac, Scopus, and EMBASE databases for all articles in English, Spanish, and French that used as keywords the terms orbital decompression and lateral wall. Two...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International ophthalmology 2021-05, Vol.41 (5), p.1929-1947
Hauptverfasser: Cruz, Antonio Augusto V., Equiterio, Bruna S. N., Cunha, Barbara S. A., Caetano, Fabiana Batista, Souza, Roque Lima
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To systematically review the literature on the deep lateral orbital decompression (DLD). Methods The authors searched the MEDLINE, Lilac, Scopus, and EMBASE databases for all articles in English, Spanish, and French that used as keywords the terms orbital decompression and lateral wall. Two articles in German were also included. Data retrieved included the number of patients and orbits operated, types of the approach employed, exophthalmometric and horizontal eye position changes, and complications. The 95% confidence intervals (CI) of the mean Hertel changes induced by the surgery were calculated from series with 15 or more data. Results Of the 204 publications initially retrieved, 131 were included. Detailed surgical techniques were analyzed from 59 articles representing 4559 procedures of 2705 patients. In 45.8% of the reports, the orbits were decompressed ab-interno. Ab-externo and rim-off techniques were used in 25.4% and 28.8% of the orbits, respectively. Mean and 95% CI intervals of Hertel changes, pooled from 15 articles, indicate that the effect of the surgery is not related to the technique and ranges from 2.5 to 4.5 mm. The rate of new onset of diplopia varied from zero to 8.6%. Several complications have been reported including dry eye, oscillopsia, temporal howling, lateral rectus damage, and bleeding. Unilateral amaurosis and subdural hematoma have been described in only one patients each. Conclusions The low rate of new-onset diplopia is the main benefit of DLD. Prospective studies are needed to compare the rate of complications induced by the 3 main surgical techniques used.
ISSN:0165-5701
1573-2630
DOI:10.1007/s10792-021-01722-3