Capillary electrophoresis with dual C4D/UV detection for simultaneously determining major metal cations and whey proteins in milk

A reliable and simple CE method with dual C4D and UV detection modes for simultaneous determination of major metal cations and whey proteins in milk samples was developed. Sample pretreatment comprised dilution, acidification to pH 4.55 with 10 mM AcOH and centrifugation. The complete separation of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2021-02, Vol.13 (6), p.801-808
Hauptverfasser: Zhao, Jing, Xu, Zhongqi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A reliable and simple CE method with dual C4D and UV detection modes for simultaneous determination of major metal cations and whey proteins in milk samples was developed. Sample pretreatment comprised dilution, acidification to pH 4.55 with 10 mM AcOH and centrifugation. The complete separation of metal cations K+, Ca2+, Na+, and Mg2+ and whey proteins α-Lac, and β-Lg could be achieved respectively within 10 min and 20 min in a simple BGE composed of 1.0 M AcOH, 12 mM l-His and 2 mM 18-crown-6 with pH 2.74 at a voltage/current of +15 kV/12.5 μA. The samples were injected hydrodynamically by a pressure of 50 mbar for 5 s, the excitation voltage and excitation frequency of the C4D detector were 80 V and 1000 kHz, respectively and the detection wavelength of UV detection was set at 200 nm. In cation analysis, the range of the detection limit was 0.05–0.10 mg L−1 for C4D detection and 0.10–0.50 mg L−1 for UV detection, respectively, and the relative standard deviations (RSD%, n = 5) of intraday and interday analysis were 0.37–0.55% and 0.46–0.79% for the relative migration time, and 2.51–4.12% and 3.65–4.91% for the peak area, respectively. In whey protein analysis, the detection limits of β-Lg and α-Lac analysis were 5 mg L−1 and 3 mg L−1, respectively and the relative standard deviations (RSD%, n = 5) of intraday and interday analysis were 0.29–0.31% and 0.43–0.48% for the migration time and 2.89–3.25% and 3.29–4.18% for the peak area, respectively. The content of four major metal cations and two whey proteins in various types of milk samples was obtained. The results indicated that the content of metal cations varied little in milk samples of different brands and prices, while the content of whey proteins, as thermosensitive active proteins, varied greatly among different heat-treated milk samples.
ISSN:1759-9660