Percutaneous Treatment of Unprotected Left Main Disease With Thin-Strut Durable-Polymer or Early Generation Thicker-Strutted and Coated Bioabsorbable-Polymer Drug-Eluting Stents in a Large-Scale Registry
The ideal drug-eluting stent (DES) for the treatment of unprotected left main coronary artery (ULMCA) is unknown. We compared percutaneous coronary intervention (PCI) using durable polymers versus early-generation, thicker strutted and coated bioabsorbable polymers for ULMCA disease. Patients who un...
Gespeichert in:
Veröffentlicht in: | Cardiovascular revascularization medicine 2021-11, Vol.32, p.43-49 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The ideal drug-eluting stent (DES) for the treatment of unprotected left main coronary artery (ULMCA) is unknown. We compared percutaneous coronary intervention (PCI) using durable polymers versus early-generation, thicker strutted and coated bioabsorbable polymers for ULMCA disease.
Patients who underwent ULMCA PCI (893 patients) from April 2008 to November 2014 were identified from the Grand-DES registry. The primary end point was 3-year target lesion failure (TLF) after propensity score matching.
The final analysis included 754 patients (84.4%) and 139 patients (15.6%) in the durable and bioabsorbable polymer group, respectively. The groups differed significantly in lesion and procedural characteristics. Propensity score-matched analysis revealed a trend toward a lower 3-year TLF in the durable polymer group (log rank p=0.071). Independent predictors of 3-year TLF were chronic kidney disease, presentation with acute myocardial infarction, and a two-stenting technique for ULMCA lesions. Definite/probable stent thrombosis rates at 3-years were low in both groups (0.8% vs. 0.7%, p=0.925).
The safety of ULCMA PCI was excellent, and durable and bioabsorbable polymer DES provided similar clinical outcomes at 3-year follow-up. Landmark analysis revealed that the durable polymer group had a lower TLF rate from 9 months. Further studies are needed to confirm these results.
•A total of 893 patients who underwent ULMCA PCI were analyzed; durable polymer vs. bioabsorbable polymer DES group.•The 3-year TLF rate was similar between the durable polymer DES group (12.7%) vs. bioabsorbable polymer DES group (15.8%).•Landmark analysis demonstrated a lower rate of TLF from 9 months in the durable polymer group. |
---|---|
ISSN: | 1553-8389 1878-0938 |
DOI: | 10.1016/j.carrev.2020.12.034 |