Safety profile of minimally invasive glaucoma surgery
PURPOSE OF REVIEWThis article reviews the safety profile of trabecular meshwork/Schlemmʼs canal-based, subconjunctival, and suprachoroidal minimally invasive glaucoma surgery (MIGS). RECENT FINDINGSProspective randomized clinical trials and metaanalyses published during the 2019–2020 review period p...
Gespeichert in:
Veröffentlicht in: | Current opinion in ophthalmology 2021-03, Vol.32 (2), p.160-168 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | PURPOSE OF REVIEWThis article reviews the safety profile of trabecular meshwork/Schlemmʼs canal-based, subconjunctival, and suprachoroidal minimally invasive glaucoma surgery (MIGS).
RECENT FINDINGSProspective randomized clinical trials and metaanalyses published during the 2019–2020 review period provided important data regarding the safety profile of trabecular meshwork/Schlemmʼs canal-based MIGS. Transient hyphema and intraocular pressure spikes are among the most common complications associated with this category of MIGS, but more serious adverse events such as cyclodialysis cleft formation may also occur. Trabecular bypass microstents and the intracanalicular scaffold are further subject to device-related complications, including malposition and obstruction. Recent case reports and retrospective case series have further characterized the safety profile of the subconjunctival gel stent, with adverse events ranging from self-limited hypotony to visually devastating endophthalmitis and suprachoroidal hemorrhage. Five-year results of the COMPASS XT study demonstrated significantly greater endothelial cell loss in patients randomized to receive CyPass Micro-Stent (Alcon Laboratories, Fort Worth, TX, USA) in combination with cataract surgery versus those who underwent cataract surgery alone, and ultimately led to a Food and Drug Administration Class I recall of the device.
SUMMARYTrabecular meshwork/Schlemmʼs canal-based procedures are generally among the safest MIGS, with mostly self-limited and nonvision-threatening complications. Subconjunctival gel stent insertion is associated with both bleb-related and stent-specific adverse events, which are similar to those observed with trabeculectomy and tube shunt surgery, respectively. Removal of the CyPass Micro-Stent from the market underscores the need for high-quality, long-term safety data regarding MIGS. |
---|---|
ISSN: | 1040-8738 1531-7021 |
DOI: | 10.1097/ICU.0000000000000731 |