Carotid IMT and Stiffness in the KiGGS 2 National Survey: Third-Generation Measurement, Quality Algorithms and Determinants of Completeness
Carotid intima–media thickness (cIMT) and carotid stiffness (CS) are important markers of atherosclerotic risk in the young. We assessed a novel third-generation method for its applicability in large population-based epidemiologic studies to determine strengths, limitations, completeness and predict...
Gespeichert in:
Veröffentlicht in: | Ultrasound in medicine & biology 2021-02, Vol.47 (2), p.296-308 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Carotid intima–media thickness (cIMT) and carotid stiffness (CS) are important markers of atherosclerotic risk in the young. We assessed a novel third-generation method for its applicability in large population-based epidemiologic studies to determine strengths, limitations, completeness and predictors of unsuccessful measurement. Four thousand seven hundred ninety-eight 14- to 31-y-old participants of the German KiGGS cohort, which is based on a nationally representative sample with 11-y follow-up, underwent B-mode ultrasound examinations of the left and right common carotid artery with semi-automatic edge detection and automatic electrocardiogram-gated real-time quality control based on a sophisticated snake algorithm and subpixel interpolation. Overall completeness was 98% for far wall cIMT and 89% for CS parameters. Plane-specific completeness varied from 92%–96% for far wall and from 64%–69% for near-wall cIMT. Obesity independently predicted unsuccessful cIMT and CS measurements with odds ratios of 12.67 (95% confidence interval: 5.50–29.19) and 7.30 (4.87–10.94) compared with non-overweight after adjustment for blood pressure, cholesterol, smoking, hazardous drinking, age, sex and sonographer. Inter- and intra-rater reliabilities of cIMT and CS parameters in a sample of 15 young adults were good or excellent. Third-generation cIMT and CS measurements in the young with semi-automatic edge-detection and automatic real-time quality control has been successfully standardized with high reliability and very high completeness in a national survey setting. This provides a strong methodological foundation for further validation of the predictive value of cIMT and CS for atherosclerotic risk in the young. |
---|---|
ISSN: | 0301-5629 1879-291X |