Cellular S-value evaluation based on real human cell models using the GATE MC package

Exploring the spatial distribution of the energy loss of ionising radiation at the subcellular level is indispensable for evaluating the radiobiological effects of targeted radionuclide therapy accurately. Believing that S-values are important for obtaining the target dose, the Committee on Medical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2021-02, Vol.168, p.109509-109509, Article 109509
Hauptverfasser: Tang, Wei, Tang, Bo, Li, Xiang, Wang, Yidi, Li, Zhanpeng, Gao, Yunan, Gao, Han, Yan, Congchong, Sun, Liang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Exploring the spatial distribution of the energy loss of ionising radiation at the subcellular level is indispensable for evaluating the radiobiological effects of targeted radionuclide therapy accurately. Believing that S-values are important for obtaining the target dose, the Committee on Medical Internal Radiation Dose (MIRD) proposed a method to obtain the cellular dosimetric parameter. However, most available data on cellular S-values were calculated based on simple geometric models, such as ellipsoids or spheres, which do not accurately reflect biological reality. To investigate the influence of the cellular model on S-values, calculations were performed for two kinds of polygon-surface phantom models of realistic, individual human cells, the lung epithelial cell model (the B2B Phantom model) and the hepatocyte model (the Liver Phantom model), using the Monte Carlo (MC) software package GATE. To analyse the influence of cell geometry on the final S-value, the differences in the S-values between the realistic cell models and simple geometric sphere and ellipsoid models with similar volumes were calculated and compared for six different combinations of source and target regions. The irradiation conditions were 0.01–1.10 MeV monoenergetic electron sources and the Auger electronic therapy nuclides Ga-67, Tc-99m, In-111, I-125 and Tl-201, which are commonly used in nuclear medicine. The S-values calculated in this study are different from the results of the simple geometry models proposed by previous researchers. Two more precise polygon-surface phantom models of realistic, individual human cells were used, which provided more accurate information about the cell dose and will be very useful for the diagnostic application of radiotherapy in the future. •1 To get a more accurate cellular S value, we used polygon-surface phantom of human real individual cells for simulation.•2 The maximum S value is between 10keV and 30keV in the case of N←Nirradiation.•3 In (Cy ← N)and (N ← Cy), the S value is most affected by the cell geometry, the maximum error is up to 65.40%.•4 The results of various cells are different, and the error of ellipsoid model is smaller.
ISSN:0969-8043
1872-9800
DOI:10.1016/j.apradiso.2020.109509