Three-Year Outcomes With a Contemporary Self-Expanding Transcatheter Valve From the Evolut PRO US Clinical Study
Paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) is associated with increased morbidity and mortality. PVR continues to plague TAVR jeopardizing long-term results. New device iterations, such as the self-expandable Evolut PRO valve, aim to decrease PVR while m...
Gespeichert in:
Veröffentlicht in: | Cardiovascular revascularization medicine 2021-05, Vol.26, p.12-16 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) is associated with increased morbidity and mortality. PVR continues to plague TAVR jeopardizing long-term results. New device iterations, such as the self-expandable Evolut PRO valve, aim to decrease PVR while maintaining optimal hemodynamics. This study sought to evaluate clinical and hemodynamic performance of the Evolut PRO system at 3 years.
The Evolut PRO US Clinical Study included 60 patients at high or extreme surgical risk undergoing TAVR with the Evolut PRO valve at 8 centers in the United States. Clinical outcomes were evaluated using Valve Academic Research Consortium (VARC)-2 criteria and included all-cause mortality, cardiovascular mortality, disabling stroke and valve complications. An independent core laboratory centrally assessed all echocardiographic measures.
At 3 years, all-cause mortality was 25.8% (cardiovascular mortality 16.5%) and the disabling stroke rate was 10.7%. There were no cases of repeat valve intervention, endocarditis or coronary obstruction. Valve thrombosis was identified in 1 patient 2 years post-procedure and was treated medically. Hemodynamics at 3 years included a mean gradient of 7.2 ± 4.5 mm Hg, an effective orifice area of 2.0 ± 0.5 cm2, and 88.2% of patients had no or trace PVR. The remaining patients had mild PVR. Most of the surviving patients (80.6%) had New York Heart Association class I symptoms at 3 years.
Outcomes at 3-years following TAVR with a contemporary self-expanding prosthesis are favorable, with no signal of valve deterioration, excellent hemodynamics including very low prevalence of PVR.
•The Evolut PRO valve includes an outer pericardial wrap intended to minimize PVR.•First report of 3-year results following TAVR with the Evolut PRO valve•88.2% of patients had no or trace PVR with no case of moderate or severe PVR.•3-Year mean gradient of 7.2 mm Hg and EOA of 2.0 cm2 unchanged from discharge. |
---|---|
ISSN: | 1553-8389 1878-0938 |
DOI: | 10.1016/j.carrev.2020.11.007 |