Chemerin isoform analysis in human biofluids using an LC/MRM-MS-based targeted proteomics approach with stable isotope-labeled standard
Targeted proteomics has advantages over earlier conventional technologies for protein detection. We developed and validated an LC/MRM-MS-based targeted proteomic method combined with immunoaffinity precipitation for the enrichment and detection of low abundance chemerin isoforms in human biofluids....
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2020-12, Vol.1139, p.79-87 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Targeted proteomics has advantages over earlier conventional technologies for protein detection. We developed and validated an LC/MRM-MS-based targeted proteomic method combined with immunoaffinity precipitation for the enrichment and detection of low abundance chemerin isoforms in human biofluids. After tryptic digestion, each chemerin isoform was characterized by isoform-specific peptides, and the absolute quantification was achieved by using stable isotope-labeled peptides as internal standards. In serum, follicular fluid and synovial fluid, a total of 6 chemerin isoforms were identified and quantified, among which a novel natural isoform 153Q was discovered for the first time. The relative content of the six chemerin isoforms in human serum was 157S ≫ 156F ≫ 158K > 154F ≥ 155A > 153Q in the ratio of 25:17:5:2.5:2.2:1, respectively. The absolute contents were in the range of 88–3.5 ng/mL. This distribution remained consistent among the 3 biofluids analyzed. Total chemerin were found to be increased in both polycystic ovary syndrome (serum and follicular fluid) and rheumatoid arthritis (serum) patients. However, chemerin isoform analysis revealed that only 156F & 157S were increased in the former, while 155A, 156F & 157S were increased in the latter. This demonstrates the potential of this method in detailed characterization of changes in chemerin isoforms that may be of clinical relevance.
[Display omitted]
•Chemerin protein was analyzed by LC/MRM-MS-based targeted proteomics approach.•Immunoaffinity purification and Stable Isotope-labeled Standard have been employed.•Six isoforms including a new 153Q of chemerin have been analyzed in human biofluids.•The levels of several specific isoforms may be associated with PCOS or RA. |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/j.aca.2020.08.062 |