Implementation and assessment of a telecytology quality assurance program

The College of American Pathologists mandates that telepathology services are included in laboratory quality management programs. The aim of this study was to assess a telecytology quality assurance (QA) process that we implemented in 2015. Each month, a cytotechnologist randomly selected 3 telecyto...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society of Cytopathology JASC 2021-03, Vol.10 (2), p.239-245
Hauptverfasser: Green, Diane M., Boivin, Megan E., Everts, Rachael M., Proskovec, Rebecca E., Yaman, Linda M., Dunn, Danielle R., Hallberg-Wallace, Karyn M., Bissell, Chloe E., Marotti, Jonathan D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The College of American Pathologists mandates that telepathology services are included in laboratory quality management programs. The aim of this study was to assess a telecytology quality assurance (QA) process that we implemented in 2015. Each month, a cytotechnologist randomly selected 3 telecytology fine-needle aspiration (FNA) cases from each cytopathologist on the FNA service that month. Data were recorded in a monthly worksheet and included onsite telecytology adequacy, final adequacy, concordance, onsite operator, cytopathologist, and reason for discrepancy, if present. The worksheet was reviewed monthly, discordant cases were re-examined, and feedback to cytologists was provided. For this study, worksheets from October 2015 to December 2019 were retrospectively reviewed. The QA program captured 488 cases, representing 25% of total cases that utilized telecytology during the evaluation period (n = 1983). The telecytology onsite assessment was concordant with the final cytologic assessment in 84% (410 of 488) of cases. The majority of discordant cases (72 of 78, 92%) were the result of an “Inadequate" onsite telecytology assessment, but a final diagnosis was able to be rendered; 92% of these cases were attributed to diagnostic material being present in cytologic preparations not available during the onsite assessment. Nine telecytology onsite interpretation errors were identified, of which 7 were provided by cytopathologists with less than 2 years of experience. Most telecytology cases with onsite assessment errors were evaluated by cytopathologists with less than 2 years of practice experience; therefore, careful monitoring of new staff should be considered when developing a telecytology QA program. •The College of American Pathologists mandates that telepathology services are included in laboratory quality management programs.•We assessed a formal telecytology quality assurance program that was implemented in 2015.•Most telecytology cases with onsite assessment errors were evaluated by cytopathologists with less than 2 years of practice experience.
ISSN:2213-2945
2213-2945
DOI:10.1016/j.jasc.2020.10.005