Noise reduction approach in pediatric abdominal CT combining deep learning and dual-energy technique

Objectives To evaluate the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based noise reduction technique for pediatric abdominal CT, compared with standard iodine concentration single-energy polychromatic CT (SECT). Methods From December 2016 to May 2...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European radiology 2021-04, Vol.31 (4), p.2218-2226
Hauptverfasser: Lee, Seunghyun, Choi, Young Hun, Cho, Yeon Jin, Lee, Seul Bi, Cheon, Jung-Eun, Kim, Woo Sun, Ahn, Chul Kyun, Kim, Jong Hyo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives To evaluate the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based noise reduction technique for pediatric abdominal CT, compared with standard iodine concentration single-energy polychromatic CT (SECT). Methods From December 2016 to May 2017, DECT with 300 mg•I/mL contrast medium was performed in 29 pediatric patients (17 boys, 12 girls; age, 2–19 years). The DECT images were reconstructed using a noise-optimized virtual monoenergetic reconstruction image (VMI) with and without a deep learning method. SECT images with 350 mg•I/mL contrast medium, performed within the last 3 months before the DECT, served as reference images. The quantitative and qualitative parameters were compared using paired t tests and Wilcoxon signed-rank tests, and the differences in radiation dose and total iodine administration were assessed. Results The linearly blended DECT showed lower attenuation and higher noise than SECT. The 60-keV VMI showed an increase in attenuation and higher noise than SECT. The combined 60-keV VMI plus deep learning images showed low noise, no difference in contrast-to-noise ratios, and overall image quality or diagnostic image quality, but showed a higher signal-to-noise ratio in the liver and lower enhancement of lesions than SECT. The overall image and diagnostic quality of lesions were maintained on the combined noise reduction approach. The CT dose index volume and total iodine administration in DECT were respectively 19.6% and 14.3% lower than those in SECT. Conclusion Low iodine concentration DECT, combined with deep learning in pediatric abdominal CT, can maintain image quality while reducing the radiation dose and iodine load, compared with standard SECT. Key Points • An image noise reduction approach combining deep learning and noise-optimized virtual monoenergetic image reconstruction can maintain image quality while reducing radiation dose and iodine load. • The 60-keV virtual monoenergetic image reconstruction plus deep learning images showed low noise, no difference in contrast-to-noise ratio, and overall image quality, but showed a higher signal-to-noise ratio in the liver and a lower enhancement of lesion than single-energy polychromatic CT. • This combination could offer a 19.6% reduction in radiation dose and a 14.3% reduction in iodine load, in comparison with a control group that underwent single-energy polychromatic CT with the standard protocol.
ISSN:0938-7994
1432-1084
DOI:10.1007/s00330-020-07349-9