Tricuspid valve in valve procedure with an Edwards S3 valve© in a 10 kg child

A 4-year-old child of 10 kg weight, with four previous sternotomies, presented a severe right heart failure, due to a severe regurgitation of his bioprosthetic tricuspid valve. A percutaneous tricuspid valve in valve procedure with an Edwards S3 valve was offered for compassionate use, and performed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiology in the young 2021-01, Vol.31 (1), p.135-137
Hauptverfasser: Betrián-Blasco, Pedro, Marti-Aguasca, Gerard, Giralt-García, Gemma
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 4-year-old child of 10 kg weight, with four previous sternotomies, presented a severe right heart failure, due to a severe regurgitation of his bioprosthetic tricuspid valve. A percutaneous tricuspid valve in valve procedure with an Edwards S3 valve was offered for compassionate use, and performed, with no complications, and significant clinical condition improvement.