Domain wall surface energy of metallic glass ribbons by the complex impedance measurement
A new method to determine the domain wall surface energy of ferromagnetic metallic glass ribbons using the measurement of the complex impedance is presented. The principle of the method is explained. Our results is of the order of 2.00x10 -4 J m 2 which tallies with the results of other researchers...
Gespeichert in:
Veröffentlicht in: | Journal of magnetism and magnetic materials 1987-06, Vol.67 (2), p.246-248 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new method to determine the domain wall surface energy of ferromagnetic metallic glass ribbons using the measurement of the complex impedance is presented. The principle of the method is explained. Our results is of the order of
2.00x10
-4
J
m
2
which tallies with the results of other researchers who used different methods. |
---|---|
ISSN: | 0304-8853 |
DOI: | 10.1016/0304-8853(87)90238-1 |