Domain wall surface energy of metallic glass ribbons by the complex impedance measurement

A new method to determine the domain wall surface energy of ferromagnetic metallic glass ribbons using the measurement of the complex impedance is presented. The principle of the method is explained. Our results is of the order of 2.00x10 -4 J m 2 which tallies with the results of other researchers...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetism and magnetic materials 1987-06, Vol.67 (2), p.246-248
Hauptverfasser: Lu, Qi, Jiang, Enyong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A new method to determine the domain wall surface energy of ferromagnetic metallic glass ribbons using the measurement of the complex impedance is presented. The principle of the method is explained. Our results is of the order of 2.00x10 -4 J m 2 which tallies with the results of other researchers who used different methods.
ISSN:0304-8853
DOI:10.1016/0304-8853(87)90238-1