Electrochemical biosensor for rapid detection of bacteria based on facile synthesis of silver wire across electrodes

The early detection of bacteria is of critical importance in addressing serious public health problems. Here, an electrochemical biosensor for rapid detection of bacteria based on facile synthesis of silver wire across electrodes was constructed. High-variable region of 16S rRNA of bacteria was used...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2020-11, Vol.168, p.112527-112527, Article 112527
Hauptverfasser: Feng, Ye, Zhou, Dan, Gao, Lujia, He, Fengjiao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The early detection of bacteria is of critical importance in addressing serious public health problems. Here, an electrochemical biosensor for rapid detection of bacteria based on facile synthesis of silver wire across electrodes was constructed. High-variable region of 16S rRNA of bacteria was used as biomarker. Polymerase-free synthesis of silver wire was introduced into electrochemical signal transduction to improve the sensitivity of electrochemical detection. The construction biosensor of proposed method is as follows: Metastable hairpin probe H1 was modified on electrode surface, biomarker can open the stem-loop structure of H1 and activates HCR. The alternate opening of the stem-loop structure of H1 and H2-AuNPs finally results in the formation of long double-stranded DNA-RNA (HCR products) -AuNPs. The formed AuNPs modified HCR products was blown in one direction using N2 to across the electrode gap. Using this HCR products as template, the silver wire was formed between the electrodes by silver deposition, and resulted in sharp change in electrical parameters of electrode. As the proof-of-concept work, multichannel series piezoelectric quartz crystal (MSPQC) was utilized as detector. The detection of Staphylococcus aureus in the concentration range from 50 to 107 CFU/mL within 100 min was achieved. The detection limit was 50 CFU/mL. Escherichia coli, Salmonella enteritidis, Listeria innocua, Pseudomonas aeruginosa and Streptococcus pneumoniae did not interfere the detection results. This newly proposed electrochemical biosensor is simple, rapid and exhibit high signal-to-noise ratio, it has great potential for being applied in food safety monitoring and clinical diagnosis. [Display omitted] •We proposed an electrochemical biosensor of bacteria based on the generation of the cross-electrode silver wire. Bacteria was detected by the sensitive response of electrochemical equipment to a sharp change in the resistance between electrodes.•The assay time was 100 min, which is far more efficient than the plate counting method (needs more than 24 h).•The biosensor is able to directly detect bacteria in lysozyme-treated human serum and milk sample.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2020.112527