Novel oxygenation technique for hypothermic machine perfusion of liver grafts: Validation in porcine Donation after Cardiac Death (DCD) liver model
Hypothermic oxygenated machine perfusion improves outcomes in Liver Transplantation, but application is limited as O2 is supplied by a stationary circuit. A novel technique of O2 “pre-charge” in a portable pump would broaden use and further mitigate ischemia damage from organ transport. Porcine DCD...
Gespeichert in:
Veröffentlicht in: | The American journal of surgery 2020-11, Vol.220 (5), p.1270-1277 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Hypothermic oxygenated machine perfusion improves outcomes in Liver Transplantation, but application is limited as O2 is supplied by a stationary circuit. A novel technique of O2 “pre-charge” in a portable pump would broaden use and further mitigate ischemia damage from organ transport.
Porcine DCD livers were randomized to static cold storage (SCS, n = 8) or hypothermic machine perfusion (HMP). HMP was stratified into HMP-O2 (n = 5), non-O2 open to air HMP-RA (n = 5), and non-O2 with sealed lids or no air HMP-NA (n = 5). HMP-O2 was “pre-charged” using 100% O2 delivered at 10 L/min over 15 min. Perfusate and tissue O2 tension (pO2), liver biopsies, and fluid chemistries were analyzed.
“Pre-charge” achieves sustained tissue and perfusate pO2 vs others. HMP-O2 results in decreased markers of hepatocyte injury: ALT (p |
---|---|
ISSN: | 0002-9610 1879-1883 |