Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial

Abstract Aims To evaluate the safety and effectiveness of pulmonary vein isolation in paroxysmal atrial fibrillation (PAF) using a standardized workflow aiming to enclose the veins with contiguous and optimized radiofrequency lesions. Methods and results This multicentre, prospective, non-randomized...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2020-11, Vol.22 (11), p.1645-1652
Hauptverfasser: Duytschaever, Mattias, Vijgen, Johan, De Potter, Tom, Scherr, Daniel, Van Herendael, Hugo, Knecht, Sebastien, Kobza, Richard, Berte, Benjamin, Sandgaard, Niels, Albenque, Jean-Paul, Szeplaki, Gabor, Stevenhagen, Yorick Jeroen, Taghji, Philippe, Wright, Matthew, Macours, Nathalie, Gupta, Dhiraj
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Aims To evaluate the safety and effectiveness of pulmonary vein isolation in paroxysmal atrial fibrillation (PAF) using a standardized workflow aiming to enclose the veins with contiguous and optimized radiofrequency lesions. Methods and results This multicentre, prospective, non-randomized study was conducted at 17 European sites. Pulmonary vein isolation was guided by VISITAG SURPOINT (VS target ≥550 on the anterior wall; ≥400 on the posterior wall) and intertag distance (≤6 mm). Atrial arrhythmia recurrence was stringently monitored with weekly and symptom-driven transtelephonic monitoring on top of standard-of-care monitoring (24-h Holter and 12-lead electrocardiogram at 3, 6, and 12 months follow-up). Three hundred and forty participants with drug refractory PAF were enrolled. Acute effectiveness (first-pass isolation proof to a 30-min wait period and adenosine challenge) was 82.4% [95% confidence interval (CI) 77.4–86.7%]. At 12-month follow-up, the rate of freedom from any documented atrial arrhythmia was 78.3% (95% CI 73.8–82.8%), while freedom from atrial arrhythmia by standard-of-care monitoring was 89.4% (95% CI 78.8–87.0%). Freedom fromrepeat ablations by the Kaplan–Meier analysis was 90.4% during 12 months of follow-up. Of the 34 patients with repeat ablations, 14 (41.2%) demonstrated full isolation of all pulmonary vein circles. Primary adverse event (PAE) rate was 3.6% (95% CI 1.9–6.3%). Conclusions The VISTAX trial demonstrated that a standardized PAF ablation workflow aiming for contiguous lesions leads to low rates of PAEs, high acute first-pass isolation rates, and 12-month freedom from arrhythmias approaching 80%. Further research is needed to improve the reproducibility of the outcomes across a wider range of centres. Clinical trial registration: ClinicalTrials.gov, number NCT03062046, https://clinicaltrials.gov/ct2/show/NCT03062046.
ISSN:1099-5129
1532-2092
DOI:10.1093/europace/euaa157