Evaluation of three fully-automated SARS-CoV-2 antibody assays

Objectives Serological assays for detection of SARS-CoV-2 antibodies are increasingly used during the COVID-19 pandemic caused by the SARS-Coronavirus-2. Here we evaluated the analytical and clinical performance of three commercially available SARS-CoV-2 antibody assays. Methods A total of 186 sampl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2020-08, Vol.58 (12), p.2113-2120
Hauptverfasser: Hörber, Sebastian, Soldo, Jelena, Relker, Lasse, Jürgens, Stefan, Guther, Julia, Peter, Silke, Lehmann, Rainer, Peter, Andreas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Serological assays for detection of SARS-CoV-2 antibodies are increasingly used during the COVID-19 pandemic caused by the SARS-Coronavirus-2. Here we evaluated the analytical and clinical performance of three commercially available SARS-CoV-2 antibody assays. Methods A total of 186 samples from 58 patients with PCR-confirmed COVID-19 infection were measured using SARS-CoV-2 antibody assays by Siemens Healthineers, Roche Diagnostics and Euroimmun. Additionally, 123 control samples, including samples collected before December 2019 and samples with potential cross-reactive antibodies were analyzed. Diagnostic specificity, sensitivity, agreement between assays and ROC curve-derived optimized thresholds were determined. Furthermore, intra- and inter-assay precision and the potential impact of interfering substances were investigated. Results SARS-CoV-2 antibody assays by Siemens and Roche showed 100% specificity. The Euroimmun assay had 98 and 100% specificity, when borderline results are considered as positive or negative, respectively. Diagnostic sensitivity for samples collected ≥14 days after PCR-positivity was 97.0, 89.4 and 95.5% using the Siemens, Roche and Euroimmun assay, respectively. Sensitivity of the Roche assay can be increased using an optimized cut-off index (0.095). However, a simultaneous decrease in specificity (98.4%) was observed. Siemens showed 95.8 and 95.5% overall agreement with results of Euroimmun and Roche assay, respectively. Euroimmun and Roche assay exhibited 92.6% overall agreement. Discordant results were observed in three COVID-19 patients and in one COVID-19 patient none of the investigated assays detected antibodies. Conclusions The investigated assays were highly specific and sensitive in detecting SARS-CoV-2 antibodies in samples obtained ≥14 days after PCR-confirmed infection. Discordant results need to be investigated in further studies.
ISSN:1434-6621
1437-4331
DOI:10.1515/cclm-2020-0975