Long-term Cost-Effectiveness of Dexcom G6 Real-time Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose in Patients With Type 1 Diabetes in the U.K

A long-term health economic analysis was performed to establish the cost-effectiveness of real-time continuous glucose monitoring (RT-CGM) (Dexcom G6) versus self-monitoring of blood glucose (SMBG) alone in U.K.-based patients with type 1 diabetes (T1D). The analysis used the IQVIA CORE Diabetes Mod...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diabetes care 2020-10, Vol.43 (10), p.2411-2417
Hauptverfasser: Roze, Stéphane, Isitt, John, Smith-Palmer, Jayne, Javanbakht, Mehdi, Lynch, Peter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A long-term health economic analysis was performed to establish the cost-effectiveness of real-time continuous glucose monitoring (RT-CGM) (Dexcom G6) versus self-monitoring of blood glucose (SMBG) alone in U.K.-based patients with type 1 diabetes (T1D). The analysis used the IQVIA CORE Diabetes Model. Clinical input data were sourced from the DIAMOND trial in adults with T1D. Simulations were performed separately in the overall population of patients with baseline HbA ≥7.5% (58 mmol/mol), and a secondary analysis was performed in patients with baseline HbA ≥8.5% (69 mmol/mol). The analysis was performed from the National Health Service health care payer perspective over a lifetime time horizon. In the overall population, G6 RT-CGM was associated with a mean incremental gain in quality-adjusted life expectancy of 1.49 quality-adjusted life years (QALYs) versus SMBG (mean [SD] 11.47 [2.04] QALYs versus 9.99 [1.84] QALYs). Total mean (SD) lifetime costs were also pounds sterling (GBP) 14,234 higher with RT-CGM (GBP 102,468 [35,681] versus GBP 88,234 [39,027]) resulting in an incremental cost-effectiveness ratio of GBP 9,558 per QALY gained. Sensitivity analyses revealed that the findings were sensitive to changes in the quality-of-life benefit associated with reduced fear of hypoglycemia and avoidance of fingerstick testing as well as the HbA benefit associated with RT-CGM use. For U.K.-based T1D patients, the G6 RT-CGM device is associated with significant improvements in clinical outcomes and, over patient lifetimes, is a cost-effective disease management option relative to SMBG on the basis of a willingness-to-pay threshold of GBP 20,000 per QALY gained.
ISSN:0149-5992
1935-5548
DOI:10.2337/dc19-2213