Cementless femoral stem fixation and leg-length discrepancy after total hip arthroplasty in different proximal femoral morphological types

Purpose Leg-length changes at total hip arthroplasty (THA) may result from too proximal position of the femoral component, i.e. not being sunk deep enough into the femoral canal due to the size and shape of both medullary canal and implant. Some femoral implants are designed to achieve such fixation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International orthopaedics 2021-04, Vol.45 (4), p.891-896
Hauptverfasser: Mavčič, Blaž, Antolič, Vane
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Leg-length changes at total hip arthroplasty (THA) may result from too proximal position of the femoral component, i.e. not being sunk deep enough into the femoral canal due to the size and shape of both medullary canal and implant. Some femoral implants are designed to achieve such fixation in the mediolateral dimension, while others also engage the bone anteroposteriorly. Our aim was to examine the relationship between proximal femoral morphology, osseointegration and leg-length equalization at THA. We asked whether the Dorr classification, femoral cortical index and canal flare index on preoperative radiographs had significant impact on THA aseptic loosening rates and post-operative leg-length discrepancy (LLD). Methods Literature review included original articles on proximal femoral morphology with post-operative LLD and other clinical outcomes of THA, published in the last decade. Case reports and biomechanical studies without clinical data were excluded. Results Higher femoral cortical index and/or canal flare index (corresponding to the Dorr type A) increases the risk of leg lengthening at THA. This is particularly notable in femoral stems with metaphyseal fixation, where high canal flare index has also been linked to osseointegration failure and implant loosening. On the other hand, lower canal flare index (corresponding to the Dorr type C) is more prevalent in the elderly population and increases late periprosthetic fracture rates and stress shielding. Even the most commonly used cementless femoral stems cannot offer optimal fit to intra-/extramedullary geometry or offset restoration in up to 30% of clinical cases. Conclusions Femoral morphology can have significant impact on post-operative LLD and osseointegration of cementless THA. Quantitative measurements of the proximal femoral canal may improve the choice of a particular implant and fixation method.
ISSN:0341-2695
1432-5195
DOI:10.1007/s00264-020-04671-1