Intrathecal use of gadobutrol for gadolinium-enhanced MR cisternography in the evaluation of patients with otorhinorrhea

Purpose Intrathecal gadolinium-enhanced MR cisternography (IGE-MRC) has a high sensitivity to detect accurate localization of cerebrospinal fluid (CSF) leakage in otorhinorrhea patients. Our purpose in this study was to describe our experience in analyzing clinically suspected CSF leakage by IGE-MRC...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Neuroradiology 2020-11, Vol.62 (11), p.1381-1387
Hauptverfasser: Dogan, Sebahat Nacar, Salt, Vefa, Korkmazer, Bora, Arslan, Serdar, Islak, Civan, Kocer, Naci, Kizilkilic, Osman
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Intrathecal gadolinium-enhanced MR cisternography (IGE-MRC) has a high sensitivity to detect accurate localization of cerebrospinal fluid (CSF) leakage in otorhinorrhea patients. Our purpose in this study was to describe our experience in analyzing clinically suspected CSF leakage by IGE-MRC by using gadobutrol with emphasis on its safety and diagnostic performance. Methods We retrospectively reviewed our imaging and clinical database for the evaluation of patients admitted to our clinic with complaints of otorhinorrhea between 2017 and 2019. Two radiologists evaluated the imaging studies independently. Consensus data was used in the analysis. Medical record review and phone call were used for the follow-up. Results Of the 85 patients included in the retrospective analysis, 82 (96.5%) had rhinorrhea and 3 (3.5%) had otorrhea. Overall, 29 patients (34.1% of all patients) underwent operation for repair of the CSF leakage site. Beta-transferrin test was available and positive in 33 patients (38.8%). Five (5.9%) patients complained headaches after the procedure and complaints were resolved with increased water intake. Postprocedurally, 3 patients (3.5%) had vertigo and 1 patient (1.2%) complained nausea but spontaneous regression were observed in a few hours. None of the patients experienced a significant complication or adverse reaction during follow-up period. Sixty-seven patients (78.8%) had medical record and telephone follow-up. Mean follow-up duration with call was 14.2 months. Conclusion IGE-MRC is a minimally invasive and highly sensitive imaging technique. The current results during our follow-up demonstrate the relative safety and feasibility of IGE-MRC by using gadobutrol to evaluate CSF leakage.
ISSN:0028-3940
1432-1920
DOI:10.1007/s00234-020-02463-3