Use of 3D Printing to Guide Creation of Fenestrations in Physician-Modified Stent-Grafts for Treatment of Thoracoabdominal Aortic Disease
Purpose: To summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3-dimensional (3D) printed models to guide on-site creation of fenestrations in aortic stent-grafts. Materials and Methods: From April 2018 to March 2019, 34 patients (mean age 58±...
Gespeichert in:
Veröffentlicht in: | Journal of endovascular therapy 2020-06, Vol.27 (3), p.385-393 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: To summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3-dimensional (3D) printed models to guide on-site creation of fenestrations in aortic stent-grafts. Materials and Methods: From April 2018 to March 2019, 34 patients (mean age 58±14 years; 24 men) with thoracoabdominal aortic disease were treated in our department. Nineteen patients had thoracoabdominal aortic dissection and 15 had thoracoabdominal aortic aneurysm. Preoperatively, a 3D printed model of the aorta was made according to computed tomography images. In the operating room, the main aortic stent-graft was completely released in the 3D printed model, and the position of each fenestration or branch was marked on the stent-graft. The fenestrations were then made using an electric pen. Wires were sewn to the edge of the fenestrations using nonabsorbable sutures. After customization, the aortic stent-graft was reloaded into the delivery sheath and deployed. Results: The printing process took ~5 hours (1 hour for image reconstruction, 3 hours for printing, and 1 hour for postprocessing). The physician-modified stent-grafts had a total of 107 fenestrations secured by 102 bridging stent-grafts, including 73 covered stents and 29 bare stents. The average procedure time was 5.6±1.2 hours, including a mean 1.3 hours for stent-graft customization. No renal insufficiency or paraplegia occurred. Two branch arteries were lost during the operation. One patient (3%) died 1 week after surgery from a retrograde dissection rupture. One patient developed a minor cerebral infarction postoperatively. The mean follow-up time was 8.5 months. There was 1 endoleak from a fenestration (coil embolized) and 4 distal ruptures of the aortic dissection (3 treated and 1 observed). Conclusion: Three-dimensional printing can be used to guide creation of fenestrated stent-grafts for the treatment of thoracoabdominal aortic diseases involving crucial branches. This technique appears to be more accurate than the traditional measurement method, with short-term follow-up demonstrating the safety and reliability of the method. However, further research and development are needed. |
---|---|
ISSN: | 1526-6028 1545-1550 |