Empiricism in Microsampling: Utilizing a Novel Lateral Flow Device and Intrinsic Normalization to Provide Accurate and Precise Clinical Analysis from a Finger Stick

Abstract Background Phlebotomy plays a key role in clinical laboratory medicine but poses certain challenges for the patient and the laboratory. Dried blood spots simplify collection and stabilize specimens effectively, but clinical reference intervals are based primarily on serum or plasma. We eval...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry (Baltimore, Md.) Md.), 2020-06, Vol.66 (6), p.821-831
Hauptverfasser: Crawford, Matthew L, Collier, Bradley B, Bradley, Meghan N, Holland, Patricia L, Shuford, Christopher M, Grant, Russell P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Phlebotomy plays a key role in clinical laboratory medicine but poses certain challenges for the patient and the laboratory. Dried blood spots simplify collection and stabilize specimens effectively, but clinical reference intervals are based primarily on serum or plasma. We evaluated use of dried separated blood plasma specimens to simplify plasma sample collection via finger stick; however, this sampling technique posed substantial analytical challenges. We discuss herein our efforts to overcome these challenges and provide accurate and precise clinical measurements. Methods Microsamples of whole blood were collected via finger stick using a collection device employing laminar-flow separation of cellular blood and plasma fractions with subsequent desiccation. Samples were analyzed on modern autoanalyzers with FDA-approved reagent and calibration systems, as well as commercially available reagents with laboratory-developed assay parameters. Measured analyte concentrations from extracted dried plasma samples were normalized to a coextracted endogenous analyte, chloride. Results Chloride normalization reduced variability incurred through extraction and undefined plasma volume. Excellent correlation of normalized measurements from dried finger-stick samples (whole blood and plasma) versus matched venous samples facilitated developing mathematical transformations to provide concordance between specimen types. Independent end-to-end performance verification yielded mean biases
ISSN:0009-9147