Development of polyoxymethylene passive sampler for assessing air concentrations of PCBs at a confined disposal facility (CDF)

In this study, 76 μm polyoxymethylene (POM) strips were evaluated as a passive air sampler (PAS) for monitoring the volatile emissions from dredged material placed in confined disposal facilities (CDF). Laboratory evaluations were used to assess the uptake kinetics, average equilibrium time, and est...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental pollution (1987) 2020-10, Vol.265 (Pt A), p.114720-114720, Article 114720
Hauptverfasser: Odetayo, Adesewa A., Reible, Danny D., Acevedo-Mackey, Damarys, Price, Cynthia, Thai, Le
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, 76 μm polyoxymethylene (POM) strips were evaluated as a passive air sampler (PAS) for monitoring the volatile emissions from dredged material placed in confined disposal facilities (CDF). Laboratory evaluations were used to assess the uptake kinetics, average equilibrium time, and estimate the POM-air partition coefficients (KPOM-A) of 16 PCB congeners. The uptake kinetics defined the effective averaging time for air sampling and ranged from about a week for dichlorobiphenyls to 2 weeks or more for tetra- and pentachlorobiphenyls at ∼20 °C under internal mass transfer resistance control which was applicable for Log KPOM-A < 8. The measured Log KPOM-A for PCBs ranged from 5.65 to 9.34 and exhibited an average deviation of 0.19 log unit from the theoretical value of KPOM-W/KAW. The PAS approach was then tested with a preliminary field application (n = 17) at a CDF allowing equilibration over 42 days. The field application focused on lower congener PCBs as a result of the estimated increase in KPOM-A and longer uptake times expected at the low ambient temperatures during the field study (average of 3.5 °C). Total PCB air concentrations around the CDF averaged 0.32 ng/m3 and varied according to proximity to placement of the dredged materials and predominant wind directions. Average PAS concentration of low congener number PCBs (15, 18, 20/28, 31) were compared to available high volume air sampler (HVAS) measurements. The PAS concentrations were within 20% of HVAS in the dominant north and south directions and showed similar trends as east and west HVAS samplers although PAS concentrations were as much as an order of magnitude below the west HVAS. [Display omitted] •Determined uptake and time to steady state on POM air sampler (PAS).•Established POM-air partition coefficients.•Sampler limited to vapor concentrations and low congener number PCBs.•PAS agreed well with HVAS measurements in dominant wind directions.
ISSN:0269-7491
1873-6424
DOI:10.1016/j.envpol.2020.114720