3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses

The use of 3D technologies is progressing in the dental field. However, little is known about the biomechanical behavior of the additive manufacturing of full-arch fixed dental prostheses (FAFDPs) for the establishment of clinical protocols. We investigated the influence of three CAD/CAM technologie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the mechanical behavior of biomedical materials 2020-08, Vol.108, p.103821-103821, Article 103821
Hauptverfasser: Barbin, Thaís, Velôso, Daniele Valente, Del Rio Silva, Letícia, Borges, Guilherme Almeida, Presotto, Anna Gabriella Camacho, Barão, Valentim Adelino Ricardo, Mesquita, Marcelo Ferraz
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The use of 3D technologies is progressing in the dental field. However, little is known about the biomechanical behavior of the additive manufacturing of full-arch fixed dental prostheses (FAFDPs) for the establishment of clinical protocols. We investigated the influence of three CAD/CAM technologies: milling (control), Selective Laser Melting (SLM) and Electron Beam Melting (EBM) for FAFDP manufacturing. Also, the effects of ceramic veneer and spark erosion on marginal misfits of FAFDPs, the stability of prosthetic screws, strain and stress on the implant-supported system, as well as the effect of chewing simulation on screw stability were evaluated. Fifteen Ti–6Al–4V alloy FAFDPs were obtained by means of CAD/CAM systems: milling, SLM and EBM (n = 5/group). The marginal misfit was analyzed according to the single-screw test protocol. Screw stability was analyzed by screw-loosening torque. Strain-gauge analysis investigated the strain on the mini-abutment analog, and photoelastic analysis investigated the stress on the peri-implant region. Subsequently, all frameworks underwent ceramic veneer and spark erosion procedures. Marginal misfit, screw-loosening and strain and stress analyses were assessed after each evaluation time: initial, ceramic veneer and spark erosion. Finally, all prostheses were subjected to 106 mechanical cycles (2 Hz/150 N), and screw-loosening was re-evaluated. Data were subjected to two-way ANOVA for repeated measures, and the Bonferroni test as a post hoc technique (α = 0.05). At the initial time, the milling group presented the lowest marginal misfit (p  0.05); spark erosion decreased the misfit values for the SLM and EBM groups (p 
ISSN:1751-6161
1878-0180
DOI:10.1016/j.jmbbm.2020.103821