Groove Wear of Tools in NC Turning of Pure Nickel

This paper analyzes the cause of groove wear of tools in turning of pure nickel using scanning electron microscope (SEM), electron probe microanalyzer (EPMA) and auger electron spectroscopy (AES). Emphasis is put on the formation mechanism of groove wear. Also described in the paper is the experimen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:CIRP annals 1986, Vol.35 (1), p.71-74
Hauptverfasser: Tan, M.T., Zhang, Y.Z.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper analyzes the cause of groove wear of tools in turning of pure nickel using scanning electron microscope (SEM), electron probe microanalyzer (EPMA) and auger electron spectroscopy (AES). Emphasis is put on the formation mechanism of groove wear. Also described in the paper is the experimental investigation of the process to minimize and eliminate the groove wear of tools.
ISSN:0007-8506
DOI:10.1016/S0007-8506(07)61841-1