Strength of Double-Row Bolted-Web Connections

Full-scale testing of double-row bolted-web connections was performed on coped and uncoped specimens. Parameters considered were the end and edge distance, bolt arrangement, and the type of hole (standard or slotted). All of the specimens failed in a block shear mode with factors of safety lower tha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of structural engineering (New York, N.Y.) N.Y.), 1983-01, Vol.109 (1), p.126-142
Hauptverfasser: Ricles, James M, Yura, Joseph A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Full-scale testing of double-row bolted-web connections was performed on coped and uncoped specimens. Parameters considered were the end and edge distance, bolt arrangement, and the type of hole (standard or slotted). All of the specimens failed in a block shear mode with factors of safety lower than predicted by the 1978 American Institute of Steel Construction (AISC) specification. An elastic finite element model was used to study the experimental behavior and develop a modified block shear failure model which shows good agreement with the test results. The finite element analysis also indicated the compression bending stresses at the cope to be twice that predicted by normal beam theory.
ISSN:0733-9445
1943-541X
DOI:10.1061/(ASCE)0733-9445(1983)109:1(126)