Reliability of measurements assessing the Lisfranc joint using weightbearing computed tomography imaging
Introduction Subtle Lisfranc joint injuries remain challenging to diagnose in clinical practice. Although of questionable accuracy, bilateral weightbearing radiographs are considered the current gold standard to assess these injuries. However, weightbearing computed tomography (WBCT), which provides...
Gespeichert in:
Veröffentlicht in: | Archives of orthopaedic and trauma surgery 2021-05, Vol.141 (5), p.775-781 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Subtle Lisfranc joint injuries remain challenging to diagnose in clinical practice. Although of questionable accuracy, bilateral weightbearing radiographs are considered the current gold standard to assess these injuries. However, weightbearing computed tomography (WBCT), which provides clearer visualization of bony landmarks, can also be used for evaluation. This study aims to design a protocol that reliably measures the distance between the medial cuneiform (C1) and second metatarsal (M2) to assess the Lisfranc joint using WBCT imaging.
Methods
Two unique methods of measuring the C1–M2 distance were designed that localize the center of the interosseous Lisfranc ligament (ILL, reference point). This reference point was located by (I) measuring a specific distance at the M2 base, or (II) approximating from nearby bony landmarks, on both axial (Ax) and coronal (Cor) WBCT images. Four parameters (I-Ax, I-Cor, II-Ax, and II-Cor) were evaluated for each of 96 specimens. Measurements were recorded by three independent observers and repeated for inter- and intra-observer agreement.
Results
In total, 96 patient image series were included and assessed in our study with an average age of 46 (19–66, SD 16.1) and average BMI of 25.8 (17.8–30.5, SD 4.3). I-Ax showed excellent agreement for intra-observer evaluation (
R
= 0.802) and good agreement for inter-observer evaluation (
R
= 0.727). I-Cor demonstrated excellent inter- (
R
= 0.814) and intra-observer (
R
= 0.840) agreement. Good agreement was found for both II-Ax and II-Cor for both intra- (
R
= 0.730,
R
= 0.708) and inter-observer (
R
= 0.705,
R
= 0.645) evaluation.
Conclusion
Measuring the C1–M2 joint space with coronal WBCT imaging through a protocol that localizes the ILL is reproducible, simple, and can potentially be utilized clinically to evaluate the Lisfranc joint. |
---|---|
ISSN: | 0936-8051 1434-3916 |
DOI: | 10.1007/s00402-020-03477-5 |