Accuracy of New Generation Intraocular Lens Calculation Formulas in Vitrectomized Eyes
To compare the prediction accuracy of new intraocular lens (IOL) calculation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO], Kane and Ladas Super formula) and traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T) with Wang-Koch (WK) axial length (AL) adjustment in...
Gespeichert in:
Veröffentlicht in: | American journal of ophthalmology 2020-09, Vol.217, p.81-90 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To compare the prediction accuracy of new intraocular lens (IOL) calculation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO], Kane and Ladas Super formula) and traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T) with Wang-Koch (WK) axial length (AL) adjustment in vitrectomized eyes.
Retrospective consecutive case-series study.
One hundred eleven eyes of 111 patients underwent uneventful phacoemulsification and enVista MX60 implantation after vitrectomy were enrolled and divided into 4 groups according to whether the vitreous cavity was filled with silicone oil. The performance of each formula was evaluated with or without lens constant optimization.
Before lens constants optimization, the mean prediction errors (MEs) of all formulas were statistically different from zero (0.14-0.46 diopters [D]) in vitrectomized eyes, except for the Kane formula. The BUII, EVO, Kane, and Haigis had relatively lower mean absolute error (MAE) and median absolute error (MedAE) with optimized constants. No significant systemic bias was found in new formulas for vitrectomized eyes with AL >26 mm (P > .05). The Hoffer Q and Holladay 1 displayed significantly hyperopic shift (0.39 and 0.51 D) for long eyes, which was corrected by the WK adjustment. There were no significant differences in the prediction accuracy of all formulas among 4 subgroups (P > .05).
The BUII, EVO, Kane, and Haigis displayed comparable performance in vitrectomized eyes with optimized constants. In vitrectomized highly myopic eyes, the new formulas and traditional formulas with WK adjustment exhibited satisfactory prediction accuracy. Silicone oil tamponade did not affect the prediction accuracy of formulas using IOLMaster 700.
•Without constants optimization, more hyperopic bias was noticed in vitrectomized eyes, except for the Kane formula.•The BUII, EVO, Kane, and Haigis displayed comparable performance with optimized constants.•New formulas and WK calculations exhibited satisfactory accuracy in vitrectomized long eyes.•Silicone oil tamponade does not affect the accuracy of formulas using an IOLMaster 700. |
---|---|
ISSN: | 0002-9394 1879-1891 |
DOI: | 10.1016/j.ajo.2020.04.035 |