Toxicity evaluation of hospital laundry wastewaters treated by microbial fuel cells and constructed wetlands
Hospital laundries generate high wastewater volumes with the presence of several contaminants. Nevertheless, few studies have investigated the toxicity of these effluents and looked for treatment alternatives that might reduce this eventual toxicity. So, the present study assessed the performance of...
Gespeichert in:
Veröffentlicht in: | The Science of the total environment 2020-08, Vol.729, p.138816-138816, Article 138816 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Hospital laundries generate high wastewater volumes with the presence of several contaminants. Nevertheless, few studies have investigated the toxicity of these effluents and looked for treatment alternatives that might reduce this eventual toxicity. So, the present study assessed the performance of an integrated system combining a microbial fuel cell (MBFC) and a constructed wetland (CW) to reduce toxic effects of wastewaters generated at a hospital laundry. After collection, raw effluents remained 7 days at the first unit (MBFC) of integrated system. Afterward, they were transferred to the second unit (CW) unit where remained more 7 days totaling a hydraulic detention time of 14 days. The toxicity evaluation involved three different organisms: Daphnia magna (acute ecotoxicity), Lactuca sativa (phytotoxicity) and Allium cepa (phytotoxicity, cytotoxicity, mutagenicity, and genotoxicity). Got results revealed an extremely acute ecotoxicity against D. magna, high phytotoxic effects in the L. sativa and A. cepa assays, and genotoxicity in the A. cepa assay for the untreated effluents. Furthermore, no significant incidence of micronuclei was observed in the raw wastewaters. Regarding the treatment, after the first stage, it was possible to verify that MBFC reduced the toxicity of the wastewaters only in some tested assays (endpoints) while after the CW (second stage) the effluents presented a complete absence of toxicity of the investigated bioassays. Therefore, the use of the integrated system combining two environmentally friendly technologies can be considered promising, since both MBFC and CW presented a complimentary effect with excellent results regarding the reduction of the overall toxicity of hospital laundry wastewaters.
[Display omitted]
•Bioassays were applied to evaluate the toxicity of hospital laundry wastewaters.•Integrated system was used for the treatment of the effluents.•Raw effluents presented extreme toxicity against D. magna and phytotoxicity towards L. sativa.•A. cepa results indicated phytotoxicity and genotoxicity of the raw wastewaters.•Integrated system efficiently reduced the overall toxicity of the investigated wastewaters. |
---|---|
ISSN: | 0048-9697 1879-1026 |
DOI: | 10.1016/j.scitotenv.2020.138816 |