Extraction of β-blockers from urine with a polymeric monolith modified with 1-allyl-3-methylimidazolium chloride in spin column format

A glycidyl methacrylate-based monolith was modified with imidazolium-based ionic liquid (IL) to be used as stationary phase for solid-phase extraction (SPE). The host monolithic support was prepared by in-situ UV polymerization in spin column format. Two approaches were developed to incorporate the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2020-07, Vol.214, p.120860-120860, Article 120860
Hauptverfasser: Mompó-Roselló, Oscar, Ribera-Castelló, Ana, Simó-Alfonso, Ernesto F., Ruiz-Angel, María José, García-Alvarez-Coque, María Celia, Herrero-Martínez, José Manuel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A glycidyl methacrylate-based monolith was modified with imidazolium-based ionic liquid (IL) to be used as stationary phase for solid-phase extraction (SPE). The host monolithic support was prepared by in-situ UV polymerization in spin column format. Two approaches were developed to incorporate the IL into the polymeric monolithic matrix: generation of IL onto the surface monolith, and copolymerization by addition of the IL to the polymerization mixture, which gave the best results. The resulting sorbent materials were morphologically characterized and used for the isolation of five β-blockers from human urine samples. All SPE steps were accomplished by centrifugation, which reduces significantly costs and time in sample treatment. Under optimal conditions, β-blockers were quantitatively retained in the modified monolith at pH 12, and desorbed with a water-methanol mixture, to be subsequently determined via HPLC with UV detection. The limits of detection ranged between 1.4 and 40 μg L−1, and the reproducibility among extraction units (expressed as relative standard deviation) was below 8.2%. The novel phase was successfully applied to the extraction of propranolol in urine samples with recoveries above 90%. [Display omitted] •Glycidyl methacrylate-based monolith was modified with ionic liquid for solid-phase extraction.•Copolymerization with ionic liquid was the best option.•Mechanically stable polymers with good flow-through properties were obtained.•Host monolithic support prepared in spin column format and separation made by centrifugation.•β-Blockers quantitatively extracted from human urine samples.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2020.120860