Indices of acceleration atelectasis and the effect of hypergravity duration on its development

New Findings What is the central question of the study? The aim was to determine the effects of duration of acceleration in the cranial–caudal direction (+Gz) on acceleration atelectasis and identify measurement techniques that can be used to assess it. What is the main finding and its importance? N...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental physiology 2021-01, Vol.106 (1), p.18-27
Hauptverfasser: Pollock, Ross D., Gates, Sonny D., Storey, Jessica A., Radcliffe, Jeremy J., Stevenson, Alec T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:New Findings What is the central question of the study? The aim was to determine the effects of duration of acceleration in the cranial–caudal direction (+Gz) on acceleration atelectasis and identify measurement techniques that can be used to assess it. What is the main finding and its importance? Non‐invasive measurement of acceleration atelectasis using electrical impedance tomography and estimates of pulmonary shunt provide more detailed assessment of acceleration atelectasis than traditional forced vital capacity measures. Using these techniques, it was found that as little as 30 s of exposure to +Gz acceleration can cause acceleration atelectasis. The results of the present study will allow a more accurate and detailed assessment of acceleration atelectasis in the future. Recently, there have been reports of acceleration atelectasis during fast jet flight despite the use of systems designed to minimize this. Before further investigation of this, indices suitable for use in applied settings and identification of acceleration durations that elicit it are required. Fifteen non‐aircrew subjects underwented five centrifuge exposures lasting 15, 30, 60 and 2 × 90 s with a plateau of +5 Gz (acceleration in the cranial‐caudal direction) while breathing 94% O2 during all but one control exposure (21% O2). Lung volumes and gas exchange limitation were assessed after each exposure. Regional lung impedance and compliance were measured after Gz exposure using electrical impedance tomography and the forced oscillatory technique, respectively. The presence of acceleration atelectasis was confirmed by reductions of 10–17% in vital and inspiratory capacity after 60 and 90 s Gz exposures (P 60 s of Gz exposure while breathing 94% O2 causes acceleration atelectasis. Electrical impedance tomography and the measurement of gas exchange limitation provide useful indicators of acceleration atelectasis. Acceleration atelectasis exerts its effects primarily through basal lung closure and reflex inspiratory limitation, both of which can be reversed by performing three maximal inspiratory breathing manoeuvres.
ISSN:0958-0670
1469-445X
DOI:10.1113/EP088495