Comparison between ultrasonography and X-ray as evaluation methods of central venous catheter positioning and their complications in pediatrics
Purpose This study evaluates the capacity of ultrasonography as a diagnostic method to confirm the proper positioning of central venous catheter (CVC) when compared to the current gold standard, chest radiography (CR). Methods A prospective study was performed including children from 0 to 14 incompl...
Gespeichert in:
Veröffentlicht in: | Pediatric surgery international 2020-05, Vol.36 (5), p.563-568 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
This study evaluates the capacity of ultrasonography as a diagnostic method to confirm the proper positioning of central venous catheter (CVC) when compared to the current gold standard, chest radiography (CR).
Methods
A prospective study was performed including children from 0 to 14 incomplete years, who underwent CVC placement between March and May 2018 at a teaching hospital in Brazil. A four-chamber view of the heart was performed with ultrasound during a rapid injection of saline solution to identify hyperechoic images and confirm the central position of the catheter. After that, a CR was performed. The diagnostic quality of ultrasound was evaluated based on accuracy, sensitivity, specificity, positive and negative predictive values.
Results
A total of 21 patients were analyzed. The mean age was 3.95 ± 4.01 years. The preferred puncture site was the right internal jugular vein (71.4%). Ultrasound accuracy to detect CVC positioning was 81%. Sensitivity, specificity and positive and negative predictive values were 33%, 100%, 100% and 79%, respectively.
Conclusion
Ultrasound is a reliable method for detection of CVC positioning. Even so, with the four-chamber cardiac view, this method is unable to identify catheters inside heart chambers, therefore, needing to confirm the positioning with CR. |
---|---|