Subjective method for tracheal tube cuff inflation: performance of anesthesiology residents and staff anesthesiologists. Prospective observational study

BACKGROUND AND OBJECTIVESPoor monitoring of tracheal tube cuff pressure may result in patient complications. The objective method of using a manometer is recommended to keep safe cuff pressure values (20-30 cm H2O). However, as manometers are not readily available, anesthesiologists use subjective m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Brazilian journal of anesthesiology (Elsevier) 2020-01, Vol.70 (1), p.9-14
Hauptverfasser: Duarte, Nadia Maria da Conceição, Caetano, Ana Maria Menezes, Arouca, Gustavo de Oliveira, Ferrreira, Andrea Tavares, Figueiredo, José Luiz de
Format: Artikel
Sprache:eng ; por
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND AND OBJECTIVESPoor monitoring of tracheal tube cuff pressure may result in patient complications. The objective method of using a manometer is recommended to keep safe cuff pressure values (20-30 cm H2O). However, as manometers are not readily available, anesthesiologists use subjective methods. We aimed to assess appropriateness of a subjective method for attaining cuff pressure and the expertise level of manometer handling among anesthesiology staff and residents in a university teaching hospital. METHODSProspective observational study, recruiting participants that performed tracheal intubation and the subjective method for tube cuff inflation. Patients with difficult airway, larynx and trachea anatomic abnormality and emergency procedures were not included. Up to 60 minutes after tracheal intubation, an investigator registered the cuff pressure using an aneroid manometer (AMBU®) connected to the tube pilot balloon. RESULTSForty-seven anesthesiologists were included in the study - 24 residents and 23 staff. Mean (SD) and medians (IQR) measured in cm H2O were, respectively, 52.5 (27.1) and 50 (30-70). We registered 83% of measurements outside the recommended pressure range, with no difference between specialists and residents. The level of expertise with the objective method was also similar in both groups. Pressure adjustments were performed in 76.6% of cases. CONCLUSIONThe subjective method for inflating the tracheal tube cuff resulted in a high rate of inadequate cuff pressures, with no difference in performance between anesthesiology specialists and residents.
ISSN:2352-2291
DOI:10.1016/j.bjan.2019.09.010