The Role of Combined Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced MRI for Differentiating Malignant From Benign Breast Lesions Presenting Washout Curve
Purpose: The aim of this study is to evaluate the diagnostic performance of combined breast magnetic resonance imaging (MRI) protocol including dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI) in patients with enhancing lesions that demonstrated washout curve and to deter...
Gespeichert in:
Veröffentlicht in: | Canadian Association of Radiologists journal 2021-08, Vol.72 (3), p.460-469 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose:
The aim of this study is to evaluate the diagnostic performance of combined breast magnetic resonance imaging (MRI) protocol including dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI) in patients with enhancing lesions that demonstrated washout curve and to determine whether applying apparent diffusion coefficient (ADC) cutoff value could improve the diagnostic value of breast MRI.
Methods:
The retrospective study included 116 patients with 116 suspicious breast lesions, which showed washout curve on DCE-MRI, who underwent subsequent biopsy. Morphologic characteristics on DCE-MRI and ADC values on DWI were evaluated. Apparent diffusion coefficient values and morphologic features of benign and malignant lesions were compared. Diagnostic values of DCE-MRI and combined MRI, including DCE-MRI and DWI (applying an ADC cutoff value) for distinguishing malignancy from benign lesions, were calculated.
Results:
Of the 116 breast lesions, 79 were malignant and 37 were benign. The ADC value of malignant tumors (median ADC, 0.72 × 10−3 mm2/s) was significantly lower than that of benign lesions (median ADC, 1.03 × 10−3 mm2/s; P < .000). The sensitivity and specificity of an ADC cutoff value of 0.89 × 10−3 mm2/s were 92% and 95%, respectively. Dynamic contrast-enhanced MRI alone presented 100% sensitivity and 59.4% specificity. Adding an ADC cutoff value of 0.89 × 10−3 mm2/s provided 100% sensitivity and 81% specificity, which would have prevented biopsy for 21.6% of benign lesions without missing any malignancies.
Conclusion:
Applying an ADC cutoff value to DCE-MRI provides an improvement in the diagnostic value of breast MRI for differentiating among lesions presenting washout curve. |
---|---|
ISSN: | 0846-5371 1488-2361 |
DOI: | 10.1177/0846537120907098 |