Evaluation of the concentration of the toxic 2,3,6,7-tetrachlorobiphenylene in air after an electrical material fire

[Display omitted] •2367-TeCBP is crucial in the determination of the risk assessment in cases of fires.•2,3,6,7-TeCBP concentration was remarkably higher than that of the 2,3,7,8-TeCDD.•2367-TeCBP was found to be a persistent micro-organic pollutant. It is known that when fires or explosions involve...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of hazardous materials 2020-07, Vol.393, p.122284-122284, Article 122284
Hauptverfasser: Colapicchioni, Valentina, Mosca, Silvia, Cerasa, Marina, Benedetti, Paolo, Guerriero, Ettore, Perilli, Mattia, Rotatori, Mauro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •2367-TeCBP is crucial in the determination of the risk assessment in cases of fires.•2,3,6,7-TeCBP concentration was remarkably higher than that of the 2,3,7,8-TeCDD.•2367-TeCBP was found to be a persistent micro-organic pollutant. It is known that when fires or explosions involve electrical systems, along with PCDDs and PCDFs, polychlorinated biphenylenes (PCBPs) are also produced. These chlorinated tricyclic aromatic pollutants were noticed in fire rubbles and after the World Trade Center destruction. However, the analytical difficulties in developing an efficient method have limited the knowledge of their environmental distribution. In light of the equipotency of 2,3,6,7-TeCBP and 2,3,7,8-TeCDD, PCBPs call for more accurate investigations. In this paper, for the first time, the level and persistence of 2,3,6,7-TeCBP have been investigated in air samples (both indoor and outdoor) after a fire broke out in an industrial building. GC–MS/MS analysis revealed that 2,3,6,7-TeCBP concentrations after the fire (3046 fg/m3 at the “epicentre”) were remarkably higher than that of the 2,3,7,8-TeCDD. Moreover, the monitoring for over two years has demonstrated the persistent nature of this compound. 2,3,6,7-TeCBP was also analyzed in two different ambient air scenario: industrial and periurban areas and in both cases its concentrations were no matter of concern, confirming the correlation of 2,3,6,7-TeCBP with fire episodes. Collectively, 2,3,6,7-TeCBP, because of its toxicity, concentration and persistence, is a crucial compound in the evaluation of the health effects correlated with fires of electrical systems.
ISSN:0304-3894
1873-3336
DOI:10.1016/j.jhazmat.2020.122284