An immunosensor for sensitive photoelectrochemical detection of Staphylococcus aureus using ZnS–Ag2S/polydopamine as photoelectric material and Cu2O as peroxidase mimic tag
We report here sensitive photoelectrochemical immunosensing of Staphylococcus aureus (S. aureus) using ZnS–Ag2S/polydopamine (PDA) as a novel photoelectric material and Cu2O as the peroxidase mimic tag. ZnS–Ag2S heterojunctions were prepared on indium tin oxide (ITO) via electrodeposition of ZnS nan...
Gespeichert in:
Veröffentlicht in: | Talanta (Oxford) 2020-05, Vol.212, p.120797-120797, Article 120797 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report here sensitive photoelectrochemical immunosensing of Staphylococcus aureus (S. aureus) using ZnS–Ag2S/polydopamine (PDA) as a novel photoelectric material and Cu2O as the peroxidase mimic tag. ZnS–Ag2S heterojunctions were prepared on indium tin oxide (ITO) via electrodeposition of ZnS nanoparticles, followed by silver ion exchange. To prepare a PDA/ZnS–Ag2S/ITO, the ZnS–Ag2S/ITO electrode was coated with PDA by self-polymerization of dopamine. The photocurrent of the PDA/ZnS–Ag2S/ITO is 1.55 times that of the ZnS–Ag2S/ITO and 7.87 times that of the ZnS/ITO, indicating a high-performance photoelectric material. A sandwiched-type photoelectrochemical immunosensor was constructed by using PDA/ZnS–Ag2S/ITO as the photoelectrode and Cu2O nanocubes as the labels. Cu2O nanocubes can serve as peroxidase mimic to generate catalytic precipitates on the immunoelectrodes, and both the Cu2O nanocubes and the generated precipitates can decrease the photocurrents of the immunoelectrodes, so a photoelectrochemical immunosensor for detecting S. aureus was constructed, showing a linear range between 10 and 107 CFU mL−1 and a low detection limit of 2 CFU mL−1. Owing to the signal amplification of Cu2O labeling, the sensitivity of the Cu2O-labeled immunosensor is 4 times that of a label-free immunosensor for detecting S. aureus, and the detection limit (2 CFU mL−1) is lower than that of a label-free immunosensor (10 CFU mL−1). This work not only provides a new and efficient photoelectric material but also demonstrated an efficient signal-amplification strategy for photoelectrochemical biosensing.
[Display omitted]
•A PDA/ZnS–Ag2S/ITO was prepared and showed excellent photoelectric performance.•A photoelectrochemical immunosensor was constructed using Cu2O nanocubes as peroxidase mimic tags.•The sensitivity of the Cu2O-labled immunosensor is 4 times that of the label-free immunosensor.•The detection limit for photoelectrochemical detection of S. aureus is 2 CFU mL−1. |
---|---|
ISSN: | 0039-9140 1873-3573 |
DOI: | 10.1016/j.talanta.2020.120797 |