Long-term results of reconstructing the joints’ articular surface in the knee and ankle with the surgical diamond instrumentation (SDI)
Purpose The surgical diamond instrumentation (SDI), a precise wet-grinding technology, promised contact healing of press-fit inserted bone and even hyaline cartilage, lacks medium- and long-term results. This retrospective study was conducted to identify risk factors associated with the failure of t...
Gespeichert in:
Veröffentlicht in: | European journal of trauma and emergency surgery (Munich : 2007) 2021-10, Vol.47 (5), p.1627-1634 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
The surgical diamond instrumentation (SDI), a precise wet-grinding technology, promised contact healing of press-fit inserted bone and even hyaline cartilage, lacks medium- and long-term results. This retrospective study was conducted to identify risk factors associated with the failure of the technique and the subjective patient outcome.
Methods
All patients treated for cartilage defects of the knee or ankle joint using the SDI technology between 2000 and 2012 with a follow-up > 1 year were included. Patients with general joint diseases or joint-related procedures, except for corrective osteotomies, were excluded. A standardized questionnaire (EQ-5D) and a questionnaire-based patient-reported outcome survey were used. Descriptive statistics were applied. A multivariate analysis examining risk factors for joint failure was performed. A
p
value |
---|---|
ISSN: | 1863-9933 1863-9941 |
DOI: | 10.1007/s00068-020-01318-z |