Photobiomodulation by light emitting diode applied sequentially does not alter performance in cycling athletes

Analyze the effects of sequential application of photobiomodulation therapy (PBMT) at different wavelengths on the performance of cycling athletes. Cyclists (48 male, mean age 33.77 years) underwent a performance evaluation through an incremental test, VO2max, blood lactate analysis, perception of e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lasers in medical science 2020-10, Vol.35 (8), p.1769-1779
Hauptverfasser: de Carvalho, Gabriela, Gobbi, Aline, Gobbi, Ronaldo Bucken, Alfredo, Damião Miranda Ngonga, do Carmo Furquim, Thales Henrique, Barbosa, Rafael Inácio, Papoti, Marcelo, de Jesus Guirro, Rinaldo Roberto
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Analyze the effects of sequential application of photobiomodulation therapy (PBMT) at different wavelengths on the performance of cycling athletes. Cyclists (48 male, mean age 33.77 years) underwent a performance evaluation through an incremental test, VO2max, blood lactate analysis, perception of effort, infrared thermography, and isokinetic evaluations. Photobiomodulation (180 J) with infrared (IR 940 ± 10 nm), red (RED 620 ± 10 nm), mixed Red, and IR (RED/IR 620 + 940 nm) or Sham (disabled device) intervention occurred on three consecutive days and was applied to the quadriceps femoris bilaterally. Reevaluations were performed 24 h after the last application, with 1 week of follow-up. A significance level of 5% was adopted, and the effect size (ES) was calculated by Cohen’s d. Results: There were no significant differences in the analyzed variables under any experimental condition ( p  > 0.005), but a moderate effect size was observed for torque peak at 60°/s on left lower limb (LLL) (ES = 0.67), average power at 60°/s of the right lower limb (RLL) (0.73), and LLL (ES = 0.65) and a considerable effect size in torque peak at 60°/s of the RLL (ES = 0.98) in the IR/RED group compared with sham 24 h after the last application. Moreover, a large effect size was observed for total time to exhaustion (ES = 1.98) and for VO2max (ES = 6.96), and a moderate effect size was seen for anaerobic threshold (ES = 0.62) in the IR/RED group compared with sham. Photobiomodulation, when not associated with training, was not able to produce a cumulative effect on the performance of cycling athletes. However, the association of two wavelengths seems to be better for increased performance. ClinicalTrials.gov Identifier: NCT03225976
ISSN:0268-8921
1435-604X
DOI:10.1007/s10103-020-02973-9