Comparison of Hybrid Vascular Grafts and Standard Grafts in Terms of Kidney Injury for the Treatment of Thoraco-Abdominal Aortic Aneurysm
Background We present a comparison of renal function outcomes during HTAR with the use of a new hybrid vascular graft (GHVG) or standard graft. Methods It is a multicenter, retrospective, observational study. Between January 2015 and March 2019, 36 patients were treated with HTAR. We compared HTAR p...
Gespeichert in:
Veröffentlicht in: | World journal of surgery 2020-06, Vol.44 (6), p.2010-2019 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
We present a comparison of renal function outcomes during HTAR with the use of a new hybrid vascular graft (GHVG) or standard graft.
Methods
It is a multicenter, retrospective, observational study. Between January 2015 and March 2019, 36 patients were treated with HTAR. We compared HTAR performed with the use of the GHVG and with the use of standard bypass graft. Primary outcome measures were hospital mortality, acute kidney injury (AKI) at 30 days and GHVG patency.
Results
Mean GHVG ischemia time was significantly lower for both renal arteries (right: GHVG, 4 ± 2 vs. standard graft, 15 ± 7 min; 95% CI 2.23–6.69,
P
|
---|---|
ISSN: | 0364-2313 1432-2323 |
DOI: | 10.1007/s00268-020-05415-3 |