The Effects of the Amount of Fluid Used in Epiduroscopic Laser Neural Discectomy Procedures on Intraocular Pressure and an Evaluation of the Ocular Findings

Abstract Introduction During epiduroscopic laser neural discectomy (ELNP) procedures, the amount of fluid used in the epidural area may cause increased intracranial pressure. This study aimed to investigate the effect of increased epidural pressure on intraocular pressure and other ocular findings d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pain medicine (Malden, Mass.) Mass.), 2020-07, Vol.21 (7), p.1357-1361
Hauptverfasser: Beyaz, Serbülent Gökhan, Ülgen, Ali Metin, Çakir, Burçin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction During epiduroscopic laser neural discectomy (ELNP) procedures, the amount of fluid used in the epidural area may cause increased intracranial pressure. This study aimed to investigate the effect of increased epidural pressure on intraocular pressure and other ocular findings due to the amount of fluid delivered to the epidural area and the rate of delivery of the fluid. Material and Methods After obtaining approval from the Ethics Committee of Sakarya University Faculty of Medicine, patients who underwent ELNP in the Department of Anesthesiology and Reanimation Department, Algology Clinic, between January 2017 and May 2017 were included in this retrospective study. To evaluate the ocular findings after the operation, measurements obtained using an optical coherence tomography device were retrieved from the patient files and evaluated. Results Data from the medical files of 52 patients from the hospital system were evaluated. There was no significant difference between preoperative and postoperative retinal nerve fiber layer (RNFL) thickness, mean central macular thickness, optic disk area, and vertical cup-to-disk ratio (P > 0.05). Conclusions Epiduroscopy procedures include intermittent or continuous infusion of saline into the epidural area. Currently, the volume of fluid that should be given to the epidural area in epiduroscopy procedures is very controversial. As a result of this study, we concluded that the amount of fluid used during ELNP, at 107.25 mL and 8.33 mL/min, had no effect on the intraocular pressure, optic disk diameter, macular thickness, or peripapillary RNFL thickness; thus, it was safe for ELNP.
ISSN:1526-2375
1526-4637
DOI:10.1093/pm/pnz347