POSTAL TLD AUDIT OF HETEROGENEITY CORRECTIONS IN RADIOTHERAPY IN THE CZECH REPUBLIC

In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 2019-12, Vol.186 (2-3), p.373-376
Hauptverfasser: Kapuciánová, Michaela, Ekendahl, Daniela
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015-2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of  70% of participants complied with the limit of 3% in the first round of this audit.